Owner & Operator's Manual
Description Page
Safety ............................................... 2
Features ........................................... 3
Applications ...................................... 3
Installation ........................................ 4
Operating Instructions....................... 5
Control Panel Description ................. 9
Specifications ................................... 10
Setup & Maintenance ....................... 12
Troubleshooting ................................ 14
Accessories ...................................... 15
Product Service ................................ 15
Warranty ........................................... Back
Vulcan Box Furnace
Air Exchange with Programmable Controls
Models: 3-550A 3-1750A
230V 9493985 9493990
Seitenansicht 0
1 2 3 4 5 6 ... 15 16

Inhaltsverzeichnis

Seite 1 - Vulcan Box Furnace

1Owner & Operator's ManualDescription PageSafety ... 2Features ...

Seite 2

10 SPECIFICATIONSPARAMETER- Temperature Range: 50°C (122°F) - 1100°C (2012°F) / 1° Resolution- Hold Time Range: 0:00 - 99:59 (hours:minutes) / 1 Min

Seite 3

113-1750A PERFORMANCE CURVESTest Conditions: Nominal line voltage, no load in the muffle only floor tray, full power applied to the muffle for the Hea

Seite 4 - INSTALLATION INSTRUCTIONS

12SETUP:The Vulcan furnace goes through a self test that lasts approx. 6 seconds each time power is applied. After this test,the display will show t

Seite 5 - OPERATIONS

13 TROUBLESHOOTINGERROR CODES:Err codes can be cleared from the display by turning the front panel power switch off and then on again. Code Descrip

Seite 6 - (0 - 99:59 mm:ss)

14 TROUBLESHOOTING THE VULCAN "3-" CONTROLPROBLEMDead, Not OperatingNo Power / DisplayNot HeatingDuring ProgramOperationDoor Too Loose orTi

Seite 7

1519 ACCESSORIESDESCRIPTION PART NUMBERTongs; 25cm (10") Stainless Steel 9390014Tongs; 30cm (12") Stainless Steel 9390015Tongs; 36 cm (14&q

Seite 8

16WARRANTYWARRANTY: Except with respect to those component parts and uses which are herein afterdescribed, DENTSPLY Neytech warrants this furnace to b

Seite 10 - SPECIFICATIONS

3 FEATURES• High Performance Hybrid MuffleLonger life and more durable than fiberFaster heating and faster cooling than firebrick• Wide operating t

Seite 11

4 INSTALLATION INSTRUCTIONSUNPACKING CAUTIONS:Carefully unpack and remove the furnace from its shipping carton. Save the carton and other packingmat

Seite 12 - SETUP & MAINTENANCE

5 OPERATIONSRUNNING A PROGRAM:The furnace has 9 three stage programs and one single temperature hold program. The furnace is sold withthe program pa

Seite 13 - TROUBLESHOOTING

6RAMP RATES (R) (0 - 40°C/minute)1. Pressing the Rate R key display's the current value of the R1 parameter followed by 3 blanks for a newvalue.

Seite 14

72. The air exchange fan produces about 20CFM of flow when operated at full speed. The vent hood or system beingused for the furnace should have suf

Seite 15 - PRODUCT SERVICE

8• For example: End = 14:30 -> _ _ :_ _• The computer uses a 24 hour clock. Therefore, the completion time will be 2:30 PM.6. Pressing the Dela

Seite 16 - Air Exch 0150 93-63-092

9EnterProgTimeTempStopStart8236547091231ESC°C / °FS SD HTR1100°C 12:30H 1Temperaturekey displays thecurrent program'stemperatures indegrees. Pr